BMS Battery Testing System
Product Detail

BMS Battery Testing System

BMS-6V

3A/5A/10A-24S~480S-200A~1000A



Application Fields


Designed for BMS calibration, verification, and functional testing during the R&D and production of electric vehicle and energy storage system battery packs. The system generates complete and detailed test reports.




Test Functions


Multi-state power

consumption test

Active-passive balancing

current test

BMS acquisition

accuracy test

Fault simulation

and testing

Switching signal

simulation and testing

Insulation resistance test

and verification

National standard charging

signal simulation

SOX test




Advantageous features


  • High-speed, stable Ethernet communication interface;


  • Integrated source-load battery simulation design supporting both charging and discharging, allowing active/passive balancing function testing;


  • Multi-range, multi-level, high-accuracy output, ideal for BMS calibration and accuracy comparison testing;


  • Supports multiple communication protocols: RS232, One-Wire, RS485, CAN, CAN FD, and Ethernet;

  • Fully compatible with national testing standards such as GB/T 34131-2023 and GB/T 38661-2020;


  • Supports secondary development for custom test workflows to improve equipment utilization;


  • Modular design allows for easy maintenance, future expansion, and upgrades;




Product parameters

Virtual Battery

Voltage range

0.1~6V

Voltage Resolution

0.01mV

Voltage Accuracy

±0.01%F.S




Current Range1

Range

±3A/±5A/±10A

Resolution

0.01mA

Accuracy

±0.01%F.S



Current Range2


Range

0~200mA

Resolution

0.01mA

精度

±0.01%F.S

Current Range3

Range

0~2mA

Resolution

0.01uA

Accuracy

±0.01%F.S

DC High Voltage Power Supply

Voltage Range

0~2000V

Resolution

100mV

Voltage Accuracy

±0.1%F.S

Current Range

0~900mA

High Accuracy Constant Current Source

Current Range

±200A~±1000A

Current Accuracy

±0.05% F.S

Resolution

1mA

Programmable Resistance Unit

Resistance Range

10Ω~12MΩ

Resistance Resolution

Resistance Accuracy

±0.15% ± 1Ω


Note:For specific models and parameters, please refer to the corresponding technical specifications